Edgetech Instruments

Model 1500 Portable Dew Point Monitor
EdgeTech Model 1500 Portable Dew Point Monitor

Portable dew point monitor Line power or battery power option
Wide measurement range (-75°C to 50°C); remote sensors possible
NIST traceable. Self contained system. Rechargeable Batteries.
Easily transportable in hard protective case.
User programmable alarm; Programmable Automatic Balance Control (ABC).

NIST rückführbar; transportables Taupunktspiegel Hygrometer; abgeschlossenes System; aufladbare Akkus oder Netzbetrieb; leicht transportierbar im Hartschalenkoffer;
großer Messbereich (-75°C bis 50°C); ); abgesetzter Sensor möglich; vom Benutzer programmierbare
Alarmschwellen; programmierbare Automatische Balance Control (ABC)


Datenblatt | Application Note


Model PDM 75-X3 Portable Dew Point Monitor
Com.Air- Dew Point MonitorPortable dew point, temperature and pressure monitor,
Wide measurement range Dewpoint -75°C to 90°C; Chilled mirror sensor full stainless
steel for measurement in corrosive gases, remote sensors possible;
Temperature -100 °C to 100 °C,
Pressure 0 to 300 psig (other possible)
Calculation of all humidity variables
NIST traceable. Self contained system. Easily transportable in hard protective case.
User programmable alarm. Programmable Automatic Balance Control (ABC).

NIST rückführbar; transportables Taupunktspiegel Hygrometer, Taupunktspiegel-Sensor
Edelstahl-Ausführung zur Messung in korrosiven Gasen, mit Temperatur- und Drucksensor
ergänzbar; abgeschlossenes System; leicht transportierbar im Hartschalenkoffer; großer
Messbereich: Taupunkttemperatur -75°C bis 75 °C°, Temperatur -100 bis 100 °C; Druck 0 bis
300 psig (andere Bereiche möglich); abgesetzter Sensor möglich; vom Benutzer
programmierbare Alarmschwellen; programmierbare Automatische Balance Control (ABC),
Berechnung anderer Feuchtekenngrößen
Datenblatt


Com.Air- Dew Point Monitor
EdgeTech Com.Air- Dew Point Monitor
- User programmable audible and visual alarms and relay contacts
- Wide measurement rang (-75 to 50°C)
NIST traceable. Virtually maintenance free. Easy to install. Self monitoring. User programmable audible and visual alarms and relay contact. Programmable Automatic Balance Control (ABC). Widest available range -103 to 122°F (-75 to 50°C), use with pump also possible

NIST rückführbar; weitgehend wartungsfrei; leicht zu installieren; mit Anzeige; vom Benutzer programmierbarer akustischer und visueller Alarm mit Relais Kontakt; programmierbare Automatische Balance Control (ABC); größt möglicher Messbereich (-75°C bis 50°C)), auch mit Pumpe ausrüstbar

Datenblatt | Application Note


DewMaster – Chilled mirror Hygrometer

EdgeTech DewMaster – Chilled mirror Hygrometer
- 3 parameter measurement: dew point, temperature, pressure
- 3 line dislpay and analog outputs
- Table top/rack mount; remote sensor possible
- Nema 4 housing option
EdgeTech field proven technology; capable of measuring dew point, absolute pressure, ppmv, and other psychrometric variables; primary chilled mirror measurement of water vapor content in gases; wide measuring range (- 90°C to 95°C); automatic correction for mirror contaminations; certified measurements against NIST traceable standards; analog and digital outputs)

Geringste Messunsicherheit der Taupunkttemperatur rückführbar auf NIST ± 0,1°C; vernachlässigbarer Bedienungsaufwand; Automatische Balance Control (ABC); großer Messbereich -90°C bis 95°C (in Abhängigkeit der Sensorwahl); gleichzeitige Messung der Taupunkttemperatur, der Gastemperatur und des Druckes; Berechnung der relativen Feuchte; absoluten Feuchte, ppmv und psychrometrischen Feuchtegrößen, analoger und digitaler Ausgang, abgesetzter Sensor möglich

Datenblatt | Application Note


Model DewTrak II- Chilled mirror transmitter

EdgeTech Model DewTrak II
Optical chilled mirror dew point transmitter
Remote, pipe, wall & duct configuration available Display,
RH & air temperature options Features 2 analog outputs,
2 programmable alarm relays and RS232C (bi-directional) output, Accuracy ±0.2°C for dew point, 0.1°C for air temperature and ±0.5%RH (typical) Dew points as low -30°C @ 25°C temperature two stage chrome plated chilled mirror 24Vdc or 85/230Vac power option, Low cost. Patented technology. No drift or hysteresis. Available with Temperature & Relative Humidity

Niedriger Preis; keine Drift und Hysterese; auch mit Temperatursensor und Berechnung der Relativen Feuchte lieferbar; Wand- und Kanalmontage möglich

Datenblatt | Application Note


Model 200M DewTrak™-Meteorological hygrometer

EdgeTech Model 200M DewTrak
- NEMA-4 enclosure Chilled mirror technique used
- Air temperature and RH options
- 25 feet of interconnecting cable included
Highest reliability. Unattended operation. Patented technology discriminates between dew & contaminants reducing maintenance. No drift or hysteresis.

Höchste Zuverlässigkeit; vernachlässigbarer Bedienungsaufwand; patentierte Technologie unterscheidet zwischen Taubelag und Verschmutzung; keine Drift und Hysterese.

Datenblatt


Model 137 - Aircraft hygrometer
EdgeTech Model 137 - Aircraft hygrometer
Measure dew points in flight
Rugged shock-mounted, military qualified
Configuration for left or right hand mounting is available
110Vac power
Rugged, field proven chilled mirror technology. Over 30 years of proven reliability. Wide measurements and operating range

Robuste, felderprobte Taupunktspiegeltechnologie; geprüfte Zuverlässigkeit in mehr als 30
Jahren; großer Mess- und Einsatzbereich;
Datenblatt


DPS3 Heated Dew point System

EdgeTech DPS1 Heated Dew point System - Heated dew point system: Measurement range (-35 to 95 °C)
- Nema 4 housing
- 3 foot heated line included
These integrated systems include microprocessor based electronics, a chilled dew point sensor, a sample flow meter / valve, a 3 feet heated sample line, Vacuum pump, assorted tubing and fittings all contained in a heated, temperature controlled NEMA-4 enclosure. Possible use electronic DewMaster

Dieses geschlossene System enthält neben einer mikroprozessor gesteuerten Elektronik einen geregelt beheizten Geräteteil mit eingebautem Taupunktspiegel- Sensor, einem Flowmeter mit Ventil, Vakuumpumpe und einer ca. 1m langen beheizten Probenleitung. Alle Teile sind betriebsfertig eingebaut in einem NEMA-4 Gehäuse; dieses Gerät kann auch mit der DewMaster Elektronik ausgerüstete werden


Datenblatt | Application Note


Dewtech 390 for low dew point measurement
Dewtech 390-A three stage peltier cooled mirror hygrometer with integral refrigeration for measure low Dewpoints from -90 °C to 20 °C. Gas temperature sensor and pressure transducer are available. Calculation of %RH, ppmv 8 line data display, serial and analog outputs, dual alarm Accuracy +/- 0,2 K Power 110 – 230 VAC

Bei diesem Messsystem wird ein Taupunktspiegel mit einem dreistufigen Peltierelement durch ein Kühlaggregat unterstützt. Es können Taupunkttemperaturen von -90 °C bis 20 °C gemessen werden. Durch die optionalen Sensoren für Gastemperatur und Druck, ist eine Berechnung der relativen Feuchte und der ppmv möglich. Es stehen ein Display mit 8 Linien, ein serieller und ein analoger Ausgang mit verschiedenen Bereichen zur Verfügung. Die Messunsicherheit beträgt +/- 0,2 K Versorgung 110 – 230 VAC

Datenblatt

S-Typ Sensor

Taupunktspiegelsensor besitzt ein zwei- oder dreistufiges Peltierelement ist sofort am entsprechenden Monitor angebracht oder kann über ein Sensorkabel mit diesem verbunden werden. Der Sensor wird als Durchflusssensor betrieben




D-Typ Sensor
Taupunktspiegelsensor mit ein- bis zweistufigem Peltierelement ist über ein Kabel mit dem Monitor verbunden. Der Sensor ist zum Einbau in Kammern oder Kanälen geeignet.

Datenblatt
Datenblatt Produktauswahl
Datenblatt Abmessungen


X3-Typ Sensor
x3_typ_sensor.png

Taupunktspiegelsensor mit dreistufigem Peltierelement ist sofort am entsprechenden Monitor angebracht oder kann über ein Sensorkabel mit diesem verbunden werden. Der Sensor wird als Durchflusssensor betrieben. Der Sensor ist ganz aus Edelstahl gefertigt und kann mit verschiedenen Kühlkörpern ausgestattet werden.
Je nach Ausführung der Kühlung beträgt der Messbereich – 90 bis 95 °C.
Bei Verwendung mit Edelstahl- oder Platinspiegel ist er auch für den Einsatz in korrosiven Gasen geeignet.
Er kann mit den Monitoren 1500-AC, PDM, Com.Air und DewMaster betrieben werden

Datenblatt


DX-Sensor
x3_typ_sensor.png

Taupunktspiegelsensor besitzt ein zweistufiges Peltierelement ist über ein Kabel mit dem Monitor verbunden. Der Sensor ist zum Einbau in Kammern oder Kanälen geeignet. Er besitzt einen zusätzlichen Kühlventilator am Sensorkörper und hat einen Messbereich von -40 °C bis 95 °C. Er kann mit den Monitoren 1500-AC, Com.Air, DewTrak II und DewMaster betrieben werden.

Datenblatt